The EDT directION Bromide Half Cell ion selective electrode has a solid state Crystalline membrane. It requires the use of a double junction reference electrode which has its outer chamber filled with the Ionic strength adjustment buffer (ISAB) detailed below.

  • Solid State Electrode
  • No internal Filling solutions required
  • Rugged Robust and Maintenance free
  • Waterproof and Submersible
  • Fixed or Detachable lead versions
  • Compatible will all pH or Ion meters
  • Long life and Low Cost

The electrode is designed for the detection and analysis of Bromide ions in aqueous solutions and is suitable for use in the laboratory and in on line analyzers.

Please note that both the ISE and the reference electrode need to be placed in the standards and samples simultaneously and should not be more than around 10cm apart. The side filling cap of the double junction reference electrode should be open during measurements and closed during storage.

The EDT Half Cell ISE can be used immediately but pre-soaking for 5 minutes in a 100 ppm Bromide solution along with the double junction reference electrode is recommended. The ionic strength of the standards and solutions should be kept constant between all standards and samples. This is achieved by the simple addition of an Ionic strength adjustment buffer (ISAB). Potassium Nitrate is ideal. A typical addition would be 1 ml of 5 molar ISAB to 100 ml of standard and sample. This solution is also used as the outer chamber reference electrode filling solution.

For low level measurements below around 50 ppm in relatively pure samples no ISAB is needed. No temperature correction is possible it is therefore important that all standards and samples should be measured at the same temperature to ensure that temperature effects are eliminated.

Begin calibration from the lowest concentration standard to avoid cross contamination. Calibration should cover the anticipated range of the samples. Rinse tips of both electrodes with de-ionised water between measurements and dab off excess water.

When the response time or slope of your crystalline ISE reduces you can lightly polish the tip with very fine emery paper to refresh.

To see a simple calibration click here. EDT directION produce a full range of Stock Standards and Ionic Strength Adjustment Buffers (ISABs) to save valuable time and give confidence in the quality of your results.

For Quick Ion analysis for under £500 use our ION Concentration Calculator.

Thumb File information
1271 Bromide Mono Manual.pdf 1.65MB 172
1271 Bromide Half Cell ISE Brochure.pdf 1.6MB 1017
Accessories
Cable length 1000mm
Cap Diameter 16mm
Commodity Code 90279050
Concentration Range 0.4-81,000 ppm
Connector BNC
Diameter 12mm
Endpoint time Typically 10-60 seconds
Interferences Sulphide, Cyanide, Iodide
length 155mm
pH range 1-12
Potential Drift 2mV per Day
Reference Type Double Junction Reference Electrode required
Resistance at 25 Deg C < 2.5 MOhm
Temperature range 5-50 Degrees C

Write a review

Note: HTML is not translated!
    Bad           Good

Bromide Half Cell ISE

  • £215.00



Recommended Essentials

Double Junction Reference Electrode (Calomel) £74.00 Double Junction Reference Electrode (Calomel) (£74.00)
Bromide 1000ppm Standard Solution 500ml £20.00 Bromide 1000ppm Standard Solution 500ml (£20.00)

Related Products

Bromide Ionic Strength Adjustment Buffer (ISAB) 500ml

Bromide Ionic Strength Adjustment Buffer (ISAB) 500ml

EDT directION manufacture a full range of standards, filling solutions and Ionic Strength Adjustment..

£30.00

Double Junction Reference Electrode (Calomel)

Double Junction Reference Electrode (Calomel)

A glass bodied reference electrode half-cell with a 12mm body and a Calomel Inner reference. Double ..

£74.00

Bromide 1000ppm Standard Solution 500ml

Bromide 1000ppm Standard Solution 500ml

EDT direction produce a wide range of stock standards to ensure that ISE calibration is both simple,..

£20.00

We deliver to all countries worldwide

For International orders call our sales hotline on +44 (0) 1304 829960