The EDT directION Fluoride Half Cell ion selective electrode has a solid state Crystalline membrane and has no internal filling solution.

  • Solid State Electrode
  • No internal Filling solutions required
  • Rugged Robust and Maintenance free
  • Waterproof and Submersible
  • Fixed or Detachable lead versions
  • Compatible will all pH or Ion meters
  • Long life and Low Cost

Response, stability and lifetime are superior to any other make of Fluoride ISE available. It requires the use of a double junction reference electrode which has its outer chamber filled with Potassium Chloride. The electrode is designed for the detection and analysis of Fluoride ions in aqueous solutions and is suitable for use in the laboratory and in on line analyzers.

Please note that both the ISE and the reference electrode need to be placed in the standards or samples simultaneously and should not be more than around 10cm apart. The side filling cap of the double junction reference electrode should be open during measurements and closed during storage .

Potassium Chloride (4M) is an ideal outer filling solution for Fluoride analysis. The EDT Half Cell ISE can be used immediately but pre-soaking for 5 minutes in a 100 ppm Fluoride solution along with the double junction reference electrode is recommended.

The ionic strength of the standards and solutions should be kept constant between all standards and samples. This is achieved by the simple addition of an Ionic strength adjustment buffer (TISAB). No temperature correction is possible it is therefore important that all standards and samples should be measured at the same temperature to ensure that temperature effects are eliminated.

Begin calibration from the lowest concentration standard to avoid cross contamination. Calibration should cover the anticipated range of the samples. Rinse tips of both electrodes with de-ionised water between measurements and dab off excess water.

When the response time or slope of your crystalline ISE reduces you can clean the tip with Methanol using a cotton bud.

To see a simple calibration click here. EDT directION produce a full range of Stock Standards and Ionic Strength Adjustment Buffers (ISABs) to save valuable time and give confidence in the quality of your results.

For Quick Ion analysis for under £500 use our ION Concentration Calculator.

Thumb File information
1221 Fluoride Half Cell ISE Brochure.pdf 1.78MB 1018
1221 Fluoride Mono Manual.pdf 1.56MB 1075
Accessories
Cable length 1000mm
Cap Diameter 16mm
Commodity Code 90279090
Concentration Range 0.02-1900 ppm
Connector BNC
Diameter 12mm
Endpoint time Typically 10-60 seconds
Interferences Hydroxide
length 155mm
pH range 4-8 pH
Potential Drift 2mV per Day
Reference Type Single Junction Reference required
Resistance at 25 Deg C < 2.5 MOhm
Temperature range 5-50 Degrees C

Write a review

Note: HTML is not translated!
    Bad           Good

Fluoride Half Cell ISE

  • £215.00


Related Products

Fluoride USB Combination ISE

Fluoride USB Combination ISE

The Fluoride USB ISE can be connected directly to a PC, notebook  or Windows tablet withou..

£450.00

Half Cell Adapter for QP451 & QP459 Instruments

Half Cell Adapter for QP451 & QP459 Instruments

The QP451 & QP459 Portable Meters are equipped with a BNC connector on the instruments. This is ..

£26.00

Tags: Electrode, ISE, Half Cell, Fluoride

We deliver to all countries worldwide

For International orders call our sales hotline on +44 (0) 1304 829960